Dashboard Gateway online · 14 devices
TR

Facility Dashboard

UD Creamery — Coffee Shop · Thursday, Jul 16, 2026 · Live data via OpLytics Sense gateway & UNOX DDC Cloud API
Assets tracked
24
imported from Revit (IFC/COBie)
Open alerts
1 crit · 3 warn
1 info notice
PM tasks
1 overdue
3 due in next 7 days
Warranty expiring
2
within 90 days
Energy today
84 kWh
−7% vs 4-week baseline

Cold storage — live OPLYTICS SENSE

UnitTempHumidityDoorStatus
Walk-in Cooler36.4 °F78%ClosedOK
Walk-in Freezer-3.8 °F—ClosedExcursion 10:42
Reach-in Cooler #138.2 °F71%ClosedOK
Temp/humidity: EM300-TH · door: WS301 magnetic contact — Milesight hardware, OpLytics-branded.

Recent alerts

Connected cooking — UNOX DDC CLOUD REST API

OvenStateProgramCavityToday
CHEFTOP MIND.Maps #1CookingCroissant — AM batch347 °F11 cycles · 9.2 kWh
BAKERTOP MIND.MapsIdle—72 °F6 cycles · 5.1 kWh
HACCP logs, cycle counts and consumption sync automatically from DDC cloud. Recipes can be pushed to ovens from the platform.

Upcoming maintenance

2D Floor Plan — Digital Twin

Imported from Revit (IFC + COBie) · every equipment family = a live asset record. Click any unit to open its record.
Sensor overlays:
COLD STORAGE COOK LINE WAREWASH / DISH PIT ICE & WATER PREP WALK-IN COOLER36.4 °F WALK-IN FREEZER-3.8 °F REACH-IN EXHAUST HOOD UNOX #1COMBI UNOX #2BAKERTOP RANGE FRYER PREP TABLE 1 PREP TABLE 2 MIXER DISHWASHER 3-COMP SINK ICE MACHINE WATERFILTRATION LP-2 T T T D D L L L C C C GATEWAY
Operational Attention / PM due Fault / critical T — Temp/Humidity (EM300-TH) D — Door contact (WS301) L — Zone leak (EM300-SLD) C — Smart CT (CT10x)

3D LiDAR Scans — As-Built Record

iGUIDE PLANIX scans organised by area and stage. The as-built scan is a spatial index into the asset register: jump to a pinned asset from its record, or open asset records from inside the scan.
Select a scan above

Assets at this location LIVE FROM TOUR

Move through the tour — assets pinned to the current position appear here.

Asset Register

Every record originates from the Revit model (IFC + COBie property sets) — enriched with docs, warranty, sensors and service history.
TagAssetCategoryModelBreakerWarrantyNext PMStatus

Maintenance & Lifecycle

Preventive schedules, reminders and the full service log — the institutional memory that survives staff turnover.
Overdue
1
hood cleaning — 12 days late
Due next 7 days
3
reminders sent to assignees
Scheduled this month
9
across 24 assets
Logged repairs YTD
31
with photos & invoices attached
TaskAssetFrequencyAssigneeNext dueStatus

How reminders work

Each PM task fires reminders at T−14, T−3 and on due date — by e-mail and mobile push. Overdue tasks escalate to the facility manager and appear on the SCOPOS advisory desk if flagged. Completing a task prompts a service-log entry (who / what / photos / cost) so history stays complete automatically.

Smart Monitoring

OpLytics Sense sensor network (Milesight hardware, OpLytics-branded) + UNOX DDC Cloud API. LoRaWAN → UG65 Gateway → platform.
⚙ Hardware stack: EM300-TH temp/humidity ×3 · WS301 door contact ×2 · EM300-SLD zone leak ×3 · CT10x smart current transformer ×4 · UG65 LoRaWAN gateway ×1 — all white-labeled OpLytics Sense. Connected cooking data via UNOX DDC Cloud REST API (Enterprise).

Walk-in Freezer — 24 h temperature excursion 10:42–11:09

Excursion to +12.3 °F correlated with freezer door open 12 min (WS301 DR-02). Root cause: delivery unload. HACCP log entry auto-created.

Walk-in Cooler — 24 h temperature in range

Setpoint 36 °F · range 34–40 °F · humidity 78% avg. Compressor duty cycle 43%.

Power — smart current transformers PREDICTIVE

Circuit / assetNowBaselineΔStatus
LP-2 / 14 — UNOX Combi #112.4 A12.1 A+2%OK
LP-2 / 8 — Walk-in cooler compressor9.7 A8.2 A+18%Rising draw
LP-2 / 22 — Dishwasher booster18.9 A19.2 A−2%OK
LP-2 / 4 — Ice machine6.1 A6.0 A+1%OK
Sustained current rise on a compressor typically means condenser coil fouling or refrigerant issues — flagged for service before product loss.

Leak detection & doors

SensorZoneReadingStatus
LK-01 · EM300-SLDDish pitDryOK
LK-02 · EM300-SLDIce machineDryOK
LK-03 · EM300-SLDWater filtrationDryOK
DR-01 · WS301Cooler door42 opens todayOK
DR-02 · WS301Freezer door28 opens · max 12 minLong-open 10:42
Gateway UG65: online · RSSI good · last uplink 38 s ago. All device batteries > 82%.

Alerts & Notifications

One stream across sensors, warranty clocks, PM schedules and connected equipment. Delivered in-app, e-mail and SMS by severity.

Capital & Lifecycle Plan

5–7 year replacement forecast built from real asset data — credible numbers for budgeting, boards and donor fundraising.
AssetInstalledUseful lifeReplace (est.)Est. costCondition signal
Walk-in cooler compressor202510 yr2031 → watch$14,500CT: draw +18%
Dishwasher (Hobart AM16)202510 yr2035$28,000Normal
UNOX Combi #1202512 yr2037$21,300DDC: normal wear
Ice machine (Hoshizaki)20258 yr2033$6,900Normal
Epoxy floor — kitchen20257 yr re-coat2032$18,000Photo log active
Hood & exhaust fan202515 yr2040$32,000Cleaning overdue
Forecast = install date + industry useful life, adjusted by live condition signals (CT draw, duty cycle, service history). Export: board packet PDF · grant application XLSX.

Work Orders

Every request, repair and confirmed service in one register — created manually, from alerts, from inspection findings, or auto-logged when a service is confirmed.
WO #AssetDescriptionRequested byCreatedStatus

Inspections

Internal maintenance routines — daily checklists, compliance walk-throughs and unresolved findings.

Daily checklist — Jul 16, 2026

Compliance walk-throughs

DateAreaInspectorFindingsStatus
Jul 10, 2026Cook lineTracy R.21 unresolved
Jun 26, 2026Cold storageJ. Alvarez1Closed
Jun 12, 2026Dish pit / warewashTracy R.0Clean

Unresolved findings

FoundAsset / AreaFindingSeverity
Jul 10, 2026Exhaust Hood + AnsulGrease accumulation above baffle filters — NFPA 96 cleaning overdueHigh
Jul 10, 2026Prep — epoxy floorEpoxy chipping near floor drain, trip/sanitation riskMedium

Vendors

All service agencies, dealers and consultants tied to this facility — every asset record links back to its vendor and service company.
CategoryCompanyContactPhoneE-mail
DealerSinger M.TuckerMark Reilly(732) 555-0141service@singermtucker.com
Service AgencyDelaware Valley RefrigerationTony Marchetti(302) 555-0122dispatch@dvrefrig.com
Service AgencyHoodPro Fire & VentScheduling(302) 555-0190schedule@hoodpro.com
Service AgencyAquaServe (Everpure / Pentair)Lisa Chen(302) 555-0163orders@aquaserve.com
Service AgencyFirst State ElectricBill Kowalski(302) 555-0155bill@firststateelectric.com
Manufacturer ServiceHobart Service — WilmingtonDispatch(302) 555-0177wilmington.service@hobart.com
Manufacturer ServiceUNOX North AmericaSupport Desk(800) 555-8669service.usa@unox.com
Manufacturer ServiceHoshizaki Mid-AtlanticDispatch(410) 555-0139service@hoshizaki-ma.com
Consultant / AdvisorySCOPOS Hospitality GroupAdvisory Desk(717) 555-0100advisory@scoposhg.com

Projects & Improvements

Close-out documents sorted by capital project / renovation, plus facility assessment reports. Upload from computer or phone.

Coffee Shop Renovation Completed Sep 05, 2025

Areas / zones: Cook line · Cold storage · Prep · Dish pit · Servery
PDFPlans — architectural & FSE
PDFCutbook — approved equipment
DWGAs-built drawings
PDFPunch report — closed
PDFShop drawings — millwork & SS fab
IMGPhotos (24)
XLSCOBie export — asset data

Creamery HVAC & Powder Exhaust In planning

Pre-design scope · RFS in progress
PDFScope memo
XLSEquipment load calculations

As-built LiDAR Scans IGUIDE

One scan per area and stage (existing conditions → as-built at close-out → periodic re-scan). Scans open inside the platform and drive the 3D view for asset records.
Area / zoneStageProjectCapturedStatus

Facility Assessment Reports

3D10-Year Facility LiDAR Scan (2026)
PDFKitchen Condition Assessment (2025)
PDFWastewater pH / BOD Study (2026)

Reports

Executive-level outputs generated from live platform data — exportable as PDF for leadership, boards and donors.

Daily Operational Brief

Jul 16: 1 critical alert (hood cleaning overdue — WO open), freezer temp excursion resolved (door open 12 min during delivery), 3 PM tasks due within 7 days, energy −7% vs 4-week baseline, all sensors online.

Compliance Snapshot

HACCP temperature logs100% complete
Hood & duct cleaning (NFPA 96)Overdue 12 days
Ansul system inspectionCurrent
Water filtration capacity85% used

Asset Risk Register

AssetRiskLive signalMitigation
Exhaust Hood + AnsulFire-code non-compliancePM overdue 12 daysWO-1042 open — HoodPro scheduled
Walk-in CoolerCompressor failure / product lossCT draw +18% vs baselineEarly coil service Jul 22
Ice MachineWater quality / scaleFilter at 85% capacityCartridge reorder drafted
AS-000